Single point load cell H10A
- Professional weighing technology
- Original BOSCHE quality
€36.00*
Available, delivery time: 1-3 days

Product information "Single point load cell H10A"
The H10A is a low profile single point load cell made from Aluminium. The load cell is suitable for small platform scales and weighing machines with accuracy class III. The load cell H10A is approved to OIML R60 up to 3000 and gives extremely accurate reproducible results, over a long term even in harsh industrial environments. By default, the load cell H10A is tested and optimised for center load sensitivity. This ensures that there will be no measurement error when the load is placed off centre, eg in a corner of a platform.
The load cell is potted and meets the requirements of protection class IP65.
Help with selecting a load cell
Typical Application
Smaller bench scales, Counting scales, Retail scales, Oxygen bottle weighing, Postal scales, Wending machines,Industrial filling and dosing processes, medical scales and pharmaceutical process.
Design
These load cells operate on the principle of the double cantilever beam and thus ensure accurate measurements. The design is insensitive to off-center force application and can be used for pushed and pulled forces. Threaded holes for attaching the sensor or the defined force introduction ease installation.
Features
- Material: Aluminium
- Capacity: 8 - 40 kg
- Accuracy class C3, Y=10.000
- Approved to OIML R60 up to 3000d
- Design: The measuring element is potted
- Protection class: IP 65
- Off center load compensated
- Load Cell is suitable for platform sizes up to 300 x 300 mm
- Robust flat design for harsh industrial environment
- Compatible with other sources
Mounting
The load cell is screwed on to two steel or aluminum plates (max. 300 x 300 mm) via the two screw-on surfaces at the front-top and rear-bottom, and a corresponding scale display or a measuring amplifier is connected. To avoid overloading, the spring deflection (bending) of the load cell should be limited with a mechanical overload stop. This mechanical stop should either be directly under the load cell or under the corner points of the platform.
Mounting example as a balance cross with stops against overload
Drawing
All specifications in mm | Subject to technical changes
Versions
Type | Nominal load, Emax | Accuracy class |
---|---|---|
H10A-C3-0008 | 8 kg | C3 |
H10A-C3-0010 | 10 kg | C3 |
H10A-C3-0015 | 15 kg | C3 |
H10A-C3-0020 | 20 kg | C3 |
H10A-C3-0030 | 30 kg | C3 |
H10A-C3-0035 | 35 kg | C3 |
H10A-C3-0040 | 40 kg | C3 |
The load cell is screwed about the two bolting up: front and back and down with two steel or aluminum plates (max. 300 x 300 mm).
Breaking load (Ed): | 300 % of emax |
---|---|
Cable length: | 1 m |
Input resistance (RLC) at reference temperature: | 404 ± 10 Ω |
Insulation resistance: | >2.000 MΩ |
Kennwert vom relativen Mindestteilungswert d. WZ (Y = Emax / vmin): | 10.000 Teile von Emax |
Limit load (EL): | 150 % of Emax |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 8 kg, 10 kg, 15 kg, 20 kg, 30 kg, 35 kg, 40 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 2,0 mV/V |
Number of division values (nLC): | 3000 |
Output resistance (RO) at reference temperature: | 350 ± 3 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 65 |
Recommended supply voltage (Uref): | 5 - 12 V |
Zero adjustment: | ± 3 % v. Cn |
Accuracy class: | C3 (nach OIML R 60) |
Material: | Aluminum |
Verifiable: | Yes |