Description
Product information "Cross shear beam X40S"
These centrally loaded special load cells have a symmetrical construction and are very precise. The structure consists of two double ended shear beams, offset by 90°. Due to this design, the loads are always introduced into the measuring body in a centred manner. Various load inputs are available for this purpose. The high-load load cell is made of high-quality alloyed tool steel, the strain gauge is encapsulated.
Help with selecting a load cell
Area of application
Vehicle scales, hopper scales, silo scales, machine scales, container scales, special scales.
Features
- Material: Alloy steel
- Rated load: up to 40,000 kg
- Construction: The measuring element is encapsulated
- Very high accuracy and linearity
- Load application: Central force introduction via load button
- Especially robust for tough continuous industrial use
Technical drawing
| Load | H | H1 | H3 | H4 | D1 | D2 | D3 | D4 |
|---|---|---|---|---|---|---|---|---|
| 10 - 40 t | 84 | 67 | 23 | Ø 150 | Ø | Ø | Ø 40 |
All dimensions in mm | Technical modifications reserved
Properties
| Breaking load (Ed): | 150 % of emax |
|---|---|
| Cable length: | On request |
| Input resistance (RLC) at reference temperature: | 385 ± 10 Ω |
| Insulation resistance: | >5.000 MΩ |
| Limit load (EL): | 120 % of Emax |
| Material: | Alloyed steel |
| Maximum permitted supply voltage (BU): | 15 V |
| Minimum preload (Emin): | 0 |
| Nominal load (Emax): | 10 - 100t |
| Nominal temperature range (BT): | - 10 ... + 40 °C |
| Nominal value (Cn): | 2,0 mV/V |
| Number of division values (nLC): | 3000 |
| Output resistance (RO) at reference temperature: | 350 ± 3 Ω |
| Protection class according to (DIN 40.050 / EN 60529): | IP 64 |
| Recommended supply voltage (Uref): | 5 - 12 V |
| Zero adjustment: | ≤ ± 1 % v. Cn |
| Accuracy class: | 0,03 |
| Material: | Alloyed Steel |