Digital Single point load cell H33A-D
- Robust with IP65 protection class
- Professional weighing technology
- Original BOSCHE quality
€82.00
Available, delivery time: 1-3 days
Description
Product information "Digital Single point load cell H33A-D"
Digital Load Cell
The H33A-D is a digital load cell made of aluminum. An integrated 24-bit signal amplifier in the cell directly converts incoming analog measurement values (mV/V) into a digital signal and outputs it. This saves costs for specialized external evaluation electronics for conversion and simplifies integration.
Communication is easily achieved through an RS-485 half-duplex interface. Each load cell can communicate separately and independently with the user through the digital output.
The digital load cell H33A-D also provides highly precise and reproducible measurement results even during long-term use. Thanks to its IP65 protection rating, the aluminum measuring body can be used in humid or dusty environments.
Note: Custom cable lengths and alternative connectors are available for larger order quantities. Please send your request to info@bosche.eu.
Help with selecting a load cell
Features
- Material: Aluminum
- Rated Load: 10, 20, 40 kg
- Easy communication via RS-485 half-duplex
- Integrated 24-bit A/D converter in the load cell for precise weight values
- Construction: The measuring element is encapsulated, Protection class: IP65
- Compensated corner load errors
- Max. platform size: 250x400 mm
- Quick integration into existing networks
- Especially robust for tough continuous use in the industrial sector
Application Area
- Shop fitting
- Self-service shelves
- Inventory applications
- Integratable into shelves, racks, or industrial vending machines
- Special machine construction
Drawing

Load introduction must not occur on the side of the cable connection, as it leads to a lateral force component.
All dimensions in mm | Technical specifications subject to change
Properties
| Breaking load (Ed): | 300 % of emax |
|---|---|
| Cable length: | 50 mm |
| Insulation resistance: | >2.000 MΩ |
| Limit load (EL): | 150 % of Emax |
| Minimum preload (Emin): | 0 |
| Nominal load (Emax): | 10 kg, 20 kg, 40 kg |
| Nominal temperature range (BT): | - 10 ... + 40 °C |
| Number of division values (nLC): | 3000 |
| Protection class according to (DIN 40.050 / EN 60529): | IP 65 |
| Recommended supply voltage (Uref): | 5 - 9 V |
| Accuracy class: | C3 (nach OIML R 60) |
| Material: | Aluminum |