Filter
Product information "Pressure force - load cell C36S"

The C36S load cells belong to multiple columns pressure force load cells and they are the classics of weighing technology. Due to the special four-column technique, the load cell is largely insensitive to eccentric loads. The load cell C36S provides even in long-term use in harsh industrial environments, highly accurate and reproducible measurement results. The Rocker has because of the agreed radii geometries a well-defined self-righting function

akademische-kappe3 Basic knowledge Load cells

icon_small_pdf Help with selecting a load cell

Applications

hopper scales, silo scales , as well as force measurements in the process industry.

Features

  • Material: Alloy Steel
  • Rated load: 20-100 t
  • Protection class: IP 66 - laser welded
  • Structure: the measuring element is laser-welded
  • Load introduction: Spherical load application knob / pad with centering
  • Particularly robust for heavy duty industrial use

Drawing

c36s-a-10t-zeichnung1   c36s-a-10t-zeichnung2

Load (t) D1 D2 D3 D4 D5 D6 H1 H2 H3 L
20, 25, 30, 50, 60 54 70  35  220  54  87  112  138,5  17 105 
75, 100 76 105  50  300  76  120  167  200  37  138

 

Mounting

c36_waegemodul

Versions

Type Nominal load, Emax Accuracy class
C36S-C3-20000 20.000 kg C3
C36S-C3-30000 30.000 kg C3
C36S-C3-30000 40.000 kg C3
C36S-C3-50000 50.000 kg C3
Breaking load (Ed): 250 % of emax
Cable length: 14 m
Input resistance (RLC) at reference temperature: 650 ± 10 Ω
Insulation resistance: >5.000 MΩ
Kennwerttoleranz: ± 0,002 mV/V
Limit load (EL): 150 % of Emax
Material: Alloyed steel
Maximum permitted supply voltage (BU): 15 V
Minimum preload (Emin): 0
Nominal load (Emax): 20.000 kg, 30.000 kg, 40.000 kg, 50.000 kg
Nominal temperature range (BT): - 10 ... + 40 °C
Nominal value (Cn): 1,0 mV/V
Number of division values (nLC): 3000
Output resistance (RO) at reference temperature: 610 ± 3 Ω
Protection class according to (DIN 40.050 / EN 60529): IP 66
Recommended supply voltage (Uref): 5 - 12 V
Zero adjustment: ≤ ± 1 % v. Cn
Accuracy class: C3 (nach OIML R 60)