Pressure force - load cell C36S
- Professional weighing technology
- Original BOSCHE quality
€504.00
Available, delivery time: on request
Description
Product information "Pressure force - load cell C36S"
The C36S load cells belong to multiple columns pressure force load cells and they are the classics of weighing technology. Due to the special four-column technique, the load cell is largely insensitive to eccentric loads. The load cell C36S provides even in long-term use in harsh industrial environments, highly accurate and reproducible measurement results. The Rocker has because of the agreed radii geometries a well-defined self-righting function
Help with selecting a load cell
Applications
hopper scales, silo scales , as well as force measurements in the process industry.
Features
- Material: Alloy Steel
- Rated load: 20-100 t
- Protection class: IP65 - laser welded
- Structure: the measuring element is laser-welded
- Load introduction: Spherical load application knob / pad with centering
- Particularly robust for heavy duty industrial use
Drawing

| Load (t) | D1 | D2 | D3 | D4 | D5 | D6 | H1 | H2 | H3 | L |
|---|---|---|---|---|---|---|---|---|---|---|
| 20, 25, 30, 50, 60 | 54 | 70 | 35 | 220 | 54 | 87 | 112 | 138,5 | 17 | 105 |
| 75, 100 | 76 | 105 | 50 | 300 | 76 | 120 | 167 | 200 | 37 | 138 |
Mounting

Versions
| Type | Nominal load, Emax | Accuracy class |
|---|---|---|
| C36S-C3-20000 | 20.000 kg | C3 |
| C36S-C3-30000 | 30.000 kg | C3 |
| C36S-C3-30000 | 40.000 kg | C3 |
| C36S-C3-50000 | 50.000 kg | C3 |
Properties
| Breaking load (Ed): | 250 % of emax |
|---|---|
| Cable length: | 14 m |
| Input resistance (RLC) at reference temperature: | 650 ± 10 Ω |
| Insulation resistance: | >5.000 MΩ |
| Kennwerttoleranz: | ± 0,002 mV/V |
| Limit load (EL): | 150 % of Emax |
| Material: | Alloyed steel |
| Maximum permitted supply voltage (BU): | 15 V |
| Minimum preload (Emin): | 0 |
| Nominal load (Emax): | 20.000 kg, 30.000 kg, 40.000 kg, 50.000 kg |
| Nominal temperature range (BT): | - 10 ... + 40 °C |
| Nominal value (Cn): | 1,0 mV/V |
| Number of division values (nLC): | 3000 |
| Output resistance (RO) at reference temperature: | 610 ± 3 Ω |
| Protection class according to (DIN 40.050 / EN 60529): | IP 66 |
| Recommended supply voltage (Uref): | 5 - 12 V |
| Zero adjustment: | ≤ ± 1 % v. Cn |
| Accuracy class: | C3 (nach OIML R 60) |
| Material: | Alloyed Steel |