Ring-Torsion load cell V50S
- Professional weighing technology
- Original BOSCHE quality
€282.00*
Available, delivery time: 1-3 days
Product information "Ring-Torsion load cell V50S"
The V50S pressure cells are used for the measurement of compressive forces in various industrial applications. The load cells are very symmetrical and compact, so it also allows the precise measurement in harsh industrial environments. The forces are always centered in the measured doses. The High load-load cell is manufactured from high alloy tool steel, laser welded and meets the requirements of protection class IP65.
Application
Weighing machines, cargo scales, silo and hopper scales, coil scales, heavy duty scales, as well as well as force measurements in the process industry.
Help with selecting a load cell
Feature
- Material: Alloy Steel
- Rated load: 10 - 150 t
- Protection class: IP65 - laser welded
- Structure: the measuring element is laser-welded
- Particularly robust for heavy duty industrial use
- Low profile
Mounting
The load cells, force transducers V50S are due to the small dimensions mainly used in hard to reach areas, or where on the basis of design specifications only little space is available.
Drawing
Load | D | D1 | D2 | H | H1 | H2 |
---|---|---|---|---|---|---|
10 - 22 t | 75 | 30 | 75 | 50 | 7 | 6,5 |
33 t | 95 | 40 | 95 | 65 | 7 | 10 |
47 t | 130 | 60 | 130 | 75 | 7 | 14 |
68 t | 130 | 60 | 130 | 85 | 7 | 14 |
100 t | 150 | 70 | 150 | 90 | 7 | 16 |
150 t | 150 | 70 | 150 | 100 | 7 | 16 |
All specifications in mm | Subject to technical changes
Versions
Type | Nominal load, Emax | Accuracy class |
---|---|---|
Ring-Torsion-Load Cell V50S-010t |
10.000 kg | 0,03 |
Ring-Torsion-Load Cell V50S-022t |
22.000 kg | 0,03 |
Ring-Torsion-Load Cell V50S-033t |
33.000 kg | 0,03 |
Ring-Torsion-Load Cell V50S-047t |
47.000 kg | 0,03 |
Ring-Torsion-Load Cell V50S-068t |
68.000 kg | 0,03 |
Ring-Torsion-Load Cell V50S-100t |
100.000 kg | 0,03 |
Ring-Torsion-Load Cell V50S-150t |
150.000 kg | 0,03 |
Breaking load (Ed): | 200 % of emax |
---|---|
Cable length: | 12 m, 16 m |
Input resistance (RLC) at reference temperature: | 1450 ± 10 Ω |
Insulation resistance: | >5.000 MΩ |
Kennwert vom relativen Mindestteilungswert d. WZ (Y = Emax / vmin): | 10.000 Teile von Emax |
Limit load (EL): | 150 % of Emax |
Material: | Alloyed steel |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 10.000 kg, 22.000 kg, 33.000 kg, 47.000 kg, 68.000 kg, 100.000 kg, 150.000 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 2,85 mV/V |
Number of division values (nLC): | 3000 |
Output resistance (RO) at reference temperature: | 1402 ± 5 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 66 |
Recommended supply voltage (Uref): | 5 - 12 V |
Zero adjustment: | ≤ ± 1 % v. Cn |
Accuracy class: | G3 |