S-Type load cell S20S
- Professional weighing technology
- Original BOSCHE quality
€101.00*
Available, delivery time: 1-3 days
Product information "S-Type load cell S20S"
The S-type load cell S20S was designed specifically for measuring tensile and pressure forces. A central coil in the upper and lower part of the load cell ensures an optimal transmission of force in the tensile and pressure direction. The S-type load cells are made of stainless steel and are characterized by high accuracy and linearity. The S-type load cell S20S is approved to OIML R60 up to 3000d (up to 500kg). The load cell S20S gives extremely accurate reproducible results over a long term even in harsh industrial environments. The load cell is potted and meets the requirements of protection class IP65. By simple integration options and a good dynamic behavior, these load cells are often offered as force transducers and calibrated in Newtons.
Help with selecting a load cell
Typical application
Hybrid scales, Hopper scales, Crane scales, Tensile testing machines, Tank weighing, filling, dosing and mixing plants, BIG-BAG scales, Medical lifter scales, Hanging hopper scales.
Features
- Material: Alloyed steel
- Capacity: 100 - 1.000 kg
- Accuracy Class C3, Y=3.500 Approved to OIML R60 up to 3000d; Test certificate number: DK0199-R60-12.27 (up to 500 kg)
- Design: The measuring element is sealed and has trimmed output
- Protection class: IP65
- Load introduction by symmetrical tapped holes at the top and bottom of the load cell
- Particularly robust for heavy duty industrial use
- Compatible with other sources
Example of installation
Drawing
Load | B | B1 |
---|---|---|
100 - 750 kg | 19,1 | 25,05 |
1000 kg | 25,4 | 30,95 |
All specifications in mm | Subject to technical changesPricelist
Versions
Type | Norminal load, Emax | Accuracy class |
---|---|---|
S20S-C3-0100 | 100 kg | C3 |
S20S-C3-0200 | 200 kg | C3 |
S20S-C3-0300 | 300 kg | C3 |
S20S-C3-0500 | 500 kg | C3 |
S20S-G3-0750 | 750 kg | 0,03 |
S20S-G3-1000 | 1000 kg | 0,03 |
Breaking load (Ed): | 200 % of emax |
---|---|
Cable length: | 3 m |
Input resistance (RLC) at reference temperature: | 400 ± 10 Ω |
Insulation resistance: | >5.000 MΩ |
Kennwert vom relativen Mindestteilungswert d. WZ (Y = Emax / vmin): | 3.500 Teile von Emax |
Limit load (EL): | 120 % of Emax |
Material: | Alloyed steel |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 1.000 kg, 100 kg, 200 kg, 300 kg, 500 kg, 750 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 2,0 mV/V |
Number of division values (nLC): | 3000 |
Output resistance (RO) at reference temperature: | 352 ± 2 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 66 |
Recommended supply voltage (Uref): | 10 - 12 V |
Zero adjustment: | ± 3 % v. Cn |
Accuracy class: | 0,03, C3 (nach OIML R 60) |