S-Type load cell S21S
- Professional weighing technology
- Original BOSCHE quality
€134.00*
Available, delivery time: 1-3 days
The S-type load cell S21S was designed specifically for measuring tensile and pressure forces. A central coil in the upper and lower part of the load cell ensures an optimal transmission of force in the tensile and pressure direction. The S-type load cell is made of alloyed tool steel and is characterized by high accuracy and linearity. The load cell S21S gives extremely accurate reproducible results, over a long term even in harsh industrial environments. The load cell is laser-welded and meets the requirements of protection class IP66. By simple integration options and a good dynamic behavior, these load cells are often offered as force transducers and calibrated in Newtons.
Help with selecting a load cell
Typical Application
Hybrid scales, overhead track scales, crane scales, Suspended Hoppers- and Tank Scales and weighing systems. Typical application also BIG-BAG Scales and process weighing applications. Force measurements, material testing and the monitoring of cable tension in lift and cranes to prevent overload. The S-cells are also frequently offered as a force transducer in Newtons calibrated
Features
- Material: Nickel plated alloy steel construction
- Capacity: 2.000 - 5.000 kg
- Protection class: IP 66
- Design: The measuring element is hermetically sealed and laser-welded
- Robust design for harsh industrial environment
- Particularly robust for heavy duty industrial use
Mounting
Traction accessories with ball joint heads
Drawing
All specifications in mm | Subject to technical changes
Versions
Type | Nominal load, Emax | Accuracy class |
---|---|---|
S21S-G3-2000 | 2.000 kg | 0,03 |
S21S-G3-5000 | 5.000 kg | 0,03 |
Breaking load (Ed): | 200 % of emax |
---|---|
Cable length: | 3 m |
Input resistance (RLC) at reference temperature: | 400 ± 2 Ω |
Insulation resistance: | >5.000 MΩ |
Limit load (EL): | 120 % of Emax |
Material: | Alloyed steel |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 2.000 kg, 5.000 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 2,0 mV/V |
Number of division values (nLC): | 3000 |
Output resistance (RO) at reference temperature: | 352 ± 3 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 66 |
Recommended supply voltage (Uref): | 5 - 12 V |
Zero adjustment: | ≤ ± 1 % v. Cn |
Accuracy class: | 0,03 |