Filter
Product information "S-Type load cell S40S"

The S-type load cell S40S was designed specifically for measuring smaller tensile and pressure forces. A central coil in the upper and lower part of the load cell ensures an optimal transmission of force in the tensile and pressure direction.
The S-type load cell is made of stainless steel and is characterized by high accuracy and linearity.
The load cell S40S gives extremely accurate reproducible results, over a long term even in harsh industrial environments.
The load cell is potted and meets the requirements of protection class IP65. By simple integration options and a good dynamic behavior, these load cells are often offered as force transducers and calibrated in Newtons.

akademische-kappe3 Basic knowledge Load cells

icon_small_pdf Help with selecting a load cell

Typical Application

Hybrid scales, hanging scales and process weighing applications. Force measurements, material testing and the monitoring of cable tension in lift and cranes to prevent overload.

Features

  • Material: Alloyed steel
  • Capacity: 20-75 kg
  • Design: The measuring element is potted and has trimmed output
  • Protection class: IP 65
  • Load introduction by symmetrical tapped holes at the top and bottom of the load cell
  • Particularly robust for heavy duty industrial use
  • Compatib

    Drawing

    s40s_zeichnung4-leiter-technik

    Load L D
    20 - 75 kg 12 mm M8

    All specifications in mm | Subject to technical changes

    Versions

    Type Nominal load, Emax Accuracy class
    S40S-G3-0020 20 kg 0,03
    S40S-G3-0030 30 kg 0,03
    S40S-G3-0050 50 kg 0,03
    S40S-C3-0075 75 kg 0,03
Breaking load (Ed): 200 % of emax
Cable length: 2,6 m
Input resistance (RLC) at reference temperature: 400 ± 2 Ω
Insulation resistance: >5.000 MΩ
Limit load (EL): 120 % of Emax
Material: Alloyed steel
Maximum permitted supply voltage (BU): 15 V
Minimum preload (Emin): 0
Nominal load (Emax): 20 kg, 30 kg, 50 kg, 75 kg
Nominal temperature range (BT): - 10 ... + 40 °C
Nominal value (Cn): 2,0 mV/V
Number of division values (nLC): 3000
Output resistance (RO) at reference temperature: 352 ± 3 Ω
Protection class according to (DIN 40.050 / EN 60529): IP 65
Recommended supply voltage (Uref): 5 - 12 V
Zero adjustment: ≤ ± 1 % v. Cn
Accuracy class: 0,03

Accessory Items

Weight Transmitter WTS
Weighing transducer
with analog output
€207.00*
Block box EK
Terminal box for
extending load cell cables
€22.00*
M
Weighing terminal MWI / GTW
Professional weighing terminal
Legal for trade
€347.00*

Similar Products

S-Type load cell S21S
Capacity: 2.000 - 5.000 kg
Alloy steel, laser-welded
€134.00*
Weighing module S40-MA
Ring screw pulling tool for
S40S load cells
€28.00*
M
S-Type load cell S20S
Capacity: 100 - 1.000 kg
Alloy steel, nickel plated
€101.00*