Single point load cell H40A
- Calibratable according to OIML R60 to 4000D
- Professional weighing technology
- Original BOSCHE quality
€56.00*
Available, delivery time: 1-3 days
The H40A is a single point load cell made from Aluminium. The load cell is suitable for bench scales, platform scales and weighing machines with accuracy class III. The load cell H40A is approved to OIML R60 up to 4000d and gives extremely accurate reproducible results, over a long term even in harsh industrial environments. Each individual load cell H40A is corner adjusted and optimised for out of center load sensitivity. This ensures that there will be no measurement error when the load is placed off centre, eg in a corner of a platform.
The load cell is potted and meets the requirements of protection class IP65
Help with selecting a load cell
Typical Application
Bench scales, platform scales, counting scales, and retail scale, belt weighing, check weighing and bag filling, dispensing scales as well as overload protection of lifting devices
Features
- Material: Aluminium
- Capacity: 100 - 500 kg
- Accuracy class up to C4 (C3 as standard, C4 on demand), Y=15.000
- Approved to OIML R60 up to 4000d
- Design: The measuring element is potted
- Protection class: IP 65
- Off center load compensated
- Load Cell is suitable for platform sizes up to 500 x 500 mm
- Robust flat design for harsh industrial environment
- Compatible with other sources
Mounting
The construction of a platform scale with this load cell is very easy. Two steel or aluminum plates of up to 500 x 500 mm are screwed onto the two screw-on surfaces at the top (front) and rear (bottom) at the cable outlet.
Drawing
All specifications in mm | Subject to technical changes
Versions
Type | Nominal load, Emax | Accuracy class |
---|---|---|
H40A-C3-0100 | 100 kg | C3 |
H40A-C3-0150 | 150 kg | C3 |
H40A-C3-0200 | 200 kg | C3 |
H40A-C3-0300 | 300 kg | C3 |
H40A-C3-0500 | 500 kg | C3 |
Breaking load (Ed): | 300 % of emax |
---|---|
Cable length: | 1,8 m |
Input resistance (RLC) at reference temperature: | 404 ± 10 Ω |
Insulation resistance: | >2.000 MΩ |
Kennwert vom relativen Mindestteilungswert d. WZ (Y = Emax / vmin): | 15.000 Teile von Emax |
Limit load (EL): | 150 % of Emax |
Material: | Aluminum |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 100 kg, 150 kg, 200 kg, 300 kg, 400 kg, 500 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 2,0 mV/V |
Number of division values (nLC): | 3000 (4000) |
Output resistance (RO) at reference temperature: | 350 ± 3 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 65 |
Recommended supply voltage (Uref): | 5 - 12 V |
Zero adjustment: | ± 0,2 % v. Cn |
Accuracy class: | C3 oder C4 (nach OIML R 60) |