Single point load cell H44A
- Professional weighing technology
- Original BOSCHE quality
€100.00*
Available, delivery time: 1-3 days
Product information "Single point load cell H44A"
The H44A is a single point load cell made from Aluminium. The load cell is suitable for bench scales, platform scales and weighing machines with accuracy class III. The load cell H44A is approved to OIML R60 up to 3000d and gives extremely accurate reproducible results, over a long term even in harsh industrial environments. Each individual load cell H44A is corner adjusted and optimised for out of center load sensitivity. This ensures that there will be no measurement error when the load is placed off centre, eg in a corner of a platform.
The load cell is potted and meets the requirements of protection class IP65.
Help with selecting a load cell
Typical Application
Belt weighing, check weighing and bag filling, dispensing scales as well as overload protection of lifting devices
Features
- Material: Aluminium
- Capacity: 100 - 750 kg
- Accuracy class C3, Y=7.000
- Approved to OIML R60 up to 3000d
- Design: The measuring element is potted
- Protection class: IP 65
- Off center load compensated
- Load Cell is suitable for platform sizes up to 400 x 500 mm (150~300 kg) 500 x 600 mm (500~750 kg)
- Robust flat design for harsh industrial environment
- Compatible with other sources
Mounting
The large screw-on surfaces and four threaded holes at the front and rear provide ideal conditions for the problem-free construction of a scale with large platform dimensions. The construction of a platform scale with this load cell is very easy. Two steel or aluminum plates of up to 600 x 800 mm are screwed on via the two screw-on surfaces above and below or at the front and back of the cable outlet.
Drawing
All specifications in mm | Subject to technical changes
Versions
Type | Nominal load, Emax | Accuracy class |
---|---|---|
H44A-C3-0100 | 100 kg | C3 |
H44A-C3-0150 | 150 kg | C3 |
H44A-C3-0200 | 200 kg | C3 |
H44A-C3-0250 | 250 kg | C3 |
H44A-C3-0300 | 300 kg | C3 |
H44A-C3-0500 | 500 kg | C3 |
H44A-C3-0750 | 750 kg | C3 |
Breaking load (Ed): | 300 % of emax |
---|---|
Cable length: | 1,8 m |
Input resistance (RLC) at reference temperature: | 404 ± 10 Ω |
Insulation resistance: | >2.000 MΩ |
Kennwert vom relativen Mindestteilungswert d. WZ (Y = Emax / vmin): | 7.000 Teile von Emax |
Limit load (EL): | 150 % of Emax |
Material: | Aluminum |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 100 kg, 150 kg, 200 kg, 250 kg, 300 kg, 500 kg, 750 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 2,0 mV/V |
Number of division values (nLC): | 3000 |
Output resistance (RO) at reference temperature: | 350 ± 3 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 65 |
Recommended supply voltage (Uref): | 5 - 12 V |
Zero adjustment: | ± 0,2 % v. Cn |
Accuracy class: | C3 (nach OIML R 60) |