Product information "Weighbeam D55S"

The low profile double shear beam load cell D55S is ideally suited for applications in harsh industrial environments. The main sector the weighbeam is uses is the steel industry.
Due to the high repeatability and high long-term stability, the load cell supplies very good results, even after perennial use.
The weighbeam is largely insensitive to side forces and don´t need further mounting parts. The load cell is particularly easy to maintain, because the connection cable is interchangeable connected via a plug connection.
The double-shear force transducers can be connected in 6-wire technology, so that even with large feed lengths or occurring temperature differences by readjusting the supply voltage accurate measurement results can be achieved.Of course, a 4-wire connection is possible. For this purpose only the supply voltage is simply short-circuited with the corresponding sense line.

akademische-kappe3 Basic knowledge Load cells

icon_small_pdf Help with selecting a load cell

Typical Application of the Weighbeam 

Metal Industry, Ladle turret scales, Ladle feries, Scrap bucket scales, Tundish cars weighing scales, Roller table scale, Hopper and Silo weighing also in high temperature enviroments.

Features

  • Material: alloy steel, nickel-plated
  • Capacity: 50.000 - 200.000 kg
  • Construction: The measuring element is sealed and protected
  • Protection class: IP 65
  • Compact and very flat construction
  • Easy assembly
  • Cable connection by plug connection IP 67
  • Robust design for heavy-duty use in the industrial sector
  • ​Optional extended operating temperature range up to 150°C
  • Compatible with other manufacturers

Mounting

Due to the special construction the weighbeam is largely insensitive to side forces and don´t need further mounting parts.

wagebalken-d55
Loads should act as closely as possible in the measuring direction. Torsional moments, off-center loading and transverse or side forces cause measuring errors and can damage the load cells permanent.

Drawing

d55s_zeichnung

Load L L1 L2 L3 L4 L5 L6 H H1 H2 H3 B B1 B2 B3
50 t 450 340 26 M20*30 80 398 40 130 105 25,5 32 120 68 110 75
100 t 500 370 30 M24*36 90 444 44 143 118 28,5 38 140 80 130 90
150 t 560 410 33 M24*36 90 500 44 158 133 32 38 160 94 150 102
200 t 620 450 33 M24*40 90 560 44 175 150 32 40 180 114 160 110
500 t 820 560 50 M42*70 150 720 80 260 230 60 40 250 156 250 160

Pin assignment

steckerbelegung

Pin A: EXC + / red
Pin B: Sense + / blue
Pin C: EXC - / black
Pin D: Sense - / yellow
Pin E: Signal + / green
Pin F: Signal - / white
Pin G: not documented

Properties

Cable length: On request
Input resistance (RLC) at reference temperature: 756 ± 6 Ω
Insulation resistance: >5.000 MΩ
Limit load (EL): 120 % of Emax
Material: Alloyed steel
Maximum permitted supply voltage (BU): 15 V
Minimum preload (Emin): 0
Nominal load (Emax): 50.000 kg, 100.000 kg, 150.000 kg, 200.000 kg, 500.000 kg
Nominal value (Cn): 1,08 (50t); 1,38 (100t); 1,57 (150t); 1,63 (200t) mV/V
Number of division values (nLC): 3000
Output resistance (RO) at reference temperature: 700 ± 4 Ω
Protection class according to (DIN 40.050 / EN 60529): IP 65
Recommended supply voltage (Uref): 5 - 12 V
Zero adjustment: ≤ ± 1 % v. Cn
Accuracy class: G3
Material: Alloyed Steel