Planar beam - Load cell P20A
- Professional weighing technology
- Original BOSCHE quality
€87.00*
Available, delivery time: 1-3 days
The planar beam load cells were developed as a low-cost solution for scales with a low construction height and that have virtually any dimensions. The load cell type P20A is a very compact and low-profile planar beam load cell, made of aluminium. The unique design enables the construction of scales with an extremely low overall height. Its special design, with wing-like mounting arms simplifies the installation and ensures optimal functional properties in every weighing system. The use of 3 or 4 load cells is an alternative to the customary single point arrangement, and offers the advantage of a virtually unlimited platform size. A 4-wire flat-ribbon cable with one connector enables fast assembly.
Help with selecting a load cell
Area of application
Bathroom scales, medical scales, flat compact scales, table scales, floor scales, sales scales, counting scales, as well as special applications in medical technology and other fields.
Features
- Very low construction height
- Material: Aluminium
- Nominal load: 11.3 - 109 kg
- Protection class: IP 65
- Structure: The measuring element has a plastic cover, and is output current calibrated
- The load cell has a 4-wire flat-ribbon cable with a connector
- Particularly robust for long-term use in industrial applications
- Approval: OIML R60 C3; test certificate number: D09-03.03
Drawing
Load | H1 | H2 | Φ D1 | Φ D2 | Deflection (mm) et Emax |
---|---|---|---|---|---|
25 lb / 11,3 kg | 3,2 | - | - | 4,2 | 0,49 |
50 lb / 22,7 kg | 4 | - | - | 6,2 | 0,48 |
100 lb / 45,4 kg | 6,4 | - | - | 6,2 | |
240 lb / 109 kg | 8 | 3,2 | 7,4 | 8 | 0,46 |
All specifications in mm | Subject to technical changes
Scheme
Breaking load (Ed): | 400 % of emax |
---|---|
Cable length: | On request |
Input resistance (RLC) at reference temperature: | 1180±50 Ω |
Insulation resistance: | >5.000 MΩ |
Kennwerttoleranz: | ± 0,1 mV/V |
Kennwert vom relativen Mindestteilungswert d. WZ (Y = Emax / vmin): | 7.500 Teile von Emax |
Limit load (EL): | 250 % von Emax |
Material: | Aluminum |
Maximum permitted supply voltage (BU): | 15 V |
Minimum preload (Emin): | 0 |
Nominal load (Emax): | 25 lb | 11,3 kg, 50 lb | 22,7 kg, 100 lb | 45,4 kg, 240 lb | 109 kg |
Nominal temperature range (BT): | - 10 ... + 40 °C |
Nominal value (Cn): | 0,9±0,1% |
Number of division values (nLC): | 3000 |
Output resistance (RO) at reference temperature: | 1000 ± 10 Ω |
Protection class according to (DIN 40.050 / EN 60529): | IP 65 |
Recommended supply voltage (Uref): | 5 - 15 V |
Zero adjustment: | ≤ ± 5% v. Cn |
Accuracy class: | C3 (nach OIML R 60) |