Filter

Product information "Strain Transducers T10N"

The T10N was designed for measuring of dynamic or static surface strain on stiff steel constructures. The Strain transducer is screwed on the component making a positive connection between the extensometer and the object. Under mechanical stress on the target construction caused strains and sprains. The sensor is simply srewed onto the component and convert the deformation on the fix platen, which is proportional to the length change, into an electrical output signal.

The strain transmitter have stainless steel construction and meets the requirements of protection class IP65. The strain transducer has been designed for applications in which there is a need to measure the deformation due to external forces acting on an existing component. Due to the small space requirements and the easy installation, the T10N are ideal for retrofitting a force measurement and load monitoring

akademische-kappe3 Basic knowledge Load cells

icon_small_pdf Help with selecting a load cell

Typical Application

Measuring of small strain on stiff structures, Load or weight measurement on supports, Surface Strain sensors measure indirectly the Clamping Force on die casting machines, Injection molding machines. Monitoring of  Presses, Stamping machines, Structural steelwork, cranes, racks, loading cranes and bridges

Features

  • Stainless steel construction
  • Capacity: 100 - 200 kg
  • Protection class: IP 65
  • Design: the strain gauge application is potted
  • Mounting: Lug with drill-holes on both sides
  • Very flat construction
  • Particularly robust for heavy duty industrial use

Mounting

The installation is done quite simply by screwing the sensor on machined surfaces. The measured surface as possible should have the same thermal coefficient of expansion as the strain sensor.

montage_t1057a2e657b7bf9

Drawing

tensiometer_t10n_zeichnung4-leiter-technik

All specifications in mm | Subject to technical changes

Breaking load (Ed): 200 % of emax
Cable length: 6 m
Input resistance (RLC) at reference temperature: 1000 ± 10 Ω
Insulation resistance: >5.000 MΩ
Kennwerttoleranz: ± 0,15 mV/V
Limit load (EL): 150 % of Emax
Material: Stainless steel
Maximum permitted supply voltage (BU): 15 V
Minimum preload (Emin): 0
Nominal load (Emax): 100 kg, 200 kg
Nominal temperature range (BT): - 10 ... + 40 °C
Nominal value (Cn): 1,0 mV/V
Number of division values (nLC): 1000
Output resistance (RO) at reference temperature: 1005 ± 3 Ω
Protection class according to (DIN 40.050 / EN 60529): IP 65
Recommended supply voltage (Uref): 5 - 12 V
Zero adjustment: ± 2 % v. Cn
Accuracy class: 0,01

Accessory Items

Block box EK
Terminal box for
extending load cell cables
€22.00*
M
Weighing terminal MWI / GTW
Professional weighing terminal
Legal for trade
€347.00*
Weight Transmitter WTS
Weighing transducer
with analog output
€207.00*

Similar Products

Rectangular load cell K90S
Capacity: 550 - 2.000 kg
Alloy steel nickleplated, laser-welded
€336.00*